Focus on pressure vessel R&D and production22year

Global sales network

Current position: Home » News » Industry Information » Correct selection of gas storage tank

产品中心

PRODUCTS CENTER

Classified by standard
GB150 Standard Storage Tank ASME Standard Storage Tank PED Standard Storage Tank
Classified By Material
Stainless Steel Storage Tank Carbon Steel Storage Tank Lined Stainless Steel Storage
Classified By Inspection
Exempted Storage Tank Need To Check The Storage Tank
Classified By Pressure
Low Pressure Storage Tank Medium Pressure Storage Tank High Pressure Storage Tank
Classified By Appearance
Vertical Storage Tank Horizontal Dtorage Tank Air Bag/Cylinder
Classified By Media
Air Storage Tank Steam Storage Tank Nitrogen Storage Tank Oxygen Storage Tank Water Tank Vacuum Tank

Service Hotline:

If you have any questions about our products and services, please contact with us in as following way:
7*24 hour hotline service

0532-66997208

Correct selection of gas storage tank

Release time:2018-11-13  Browse:442
gas storage tank is commonly used in industry An industrial equipment for purifying and compressing air is also one of the special safety equipments strictly regulated by the state. It also directly affects the unloading of air compressors, so it plays a vital role in the correct selection of gas storage tanks: /span>
First of all, we should select the products produced by the company with the corresponding special equipment production qualification and strictly implement the GB/T150-2011 "Pressure Vessel" standard.
Secondly, many customers choose inverter air compressors due to fluctuations in gas consumption. In fact, a large part of them can directly use relatively large gas storage. Tanks reduce the unloading time of the air compressor, which saves a lot of energy.
The gas tank can be selected according to the following formula:
V=N×Q÷(P+1)
V: Gas tank volume
Q: Air compressor displacement
P: exhaust pressure
N is a parameter. The recommended value for customers with stable gas consumption is 1~2. The recommended value is fluctuating frequently but the fluctuation value is not large. 3. If the fluctuation is frequent and the fluctuation value is large, it is recommended to take the value above 4.

1. When the air compressor or the external pipe network suddenly stops supplying air, if the pneumatic equipment needs to work for a certain period of time, the calculation formula of the gas tank volume is :
V≥PaQmaxT/60(P1-P2) (L)
2. If the suction flow of the air compressor is selected according to the average air consumption of the pneumatic system, when the pneumatic system is working at the maximum air consumption , then
The formula for the volume of the gas tank is:
V1= (Qmax-Qsa) Pa /P*(T'/60) (L) (1)
V=P*V1 /(P1-P2) (2)
From (1), (2):
V=(Qmax-Qsa)Pa*T/(60(P3-P2))
where: P1: the pressure at which the air supply is stopped, MPa
P2: Minimum working pressure allowed for pneumatic systems, MPa
P3: maximum working pressure of the gas tank, MPa
Pa: atmospheric pressure, Pa=0.1MPa
Qmax: Maximum air consumption of the pneumatic system, L/min (standard state)
T: The time during which the pneumatic system should be maintained after the gas supply is stopped, s
Qsa: Average air consumption of pneumatic systems, L/min (standard state)
P: pressure of pneumatic system, MPa (absolute pressure), Pa=0.1MPa
T’: working time of the pneumatic system at maximum air consumption, s
V1: Effective gas storage volume of the gas tank